Welcome to your 2365 625 Electrical design. This mock exam is not a substitute for proper teaching or revision and should only be used as a resource to prepare learners for the exam. The questions (along with the wording and diagrams) contained within the bank of this exam are purely made up by our lecturers and not copied from any actual qualification exam. So while this is an excellent free revision resource, please do not rely on these exam questions alone to help you be successful within your qualifications. When you are ready, please press "start quiz".
1.
Which of the following is a re-wireable fuse?
2.
If a ring final circuit has a 32A fuse and a 230 V supply, the maximum power available at any one time should be no more than?
3.
What maximum spacing should clips for 2.5mm² T+E, when ran horizontally be at?
4.
Which of these is not covered by the scope of BS7671?
5.
When cabling is routed through insulation, the rated?
6.
The overall diameter of large CSA multicore armoured cables may be reduced by?
7.
The IET Wiring Regulations would not normally apply to which of the following items of electrical equipment?
8.
Which one of the following devices would be BEST suited to fixing 20mm² pvc conduit saddles to a concrete wall?
9.
At what depth should a Steel Wired Armoured (SWA) cable be buried on an agricultural premises?
10.
Which of the following is a miniture circuit breaker?
11.
If class II and class I cabling is in the same cable space, how should it be placed?
12.
Spring toggles are used to fix electrical equipment to?
13.
Where saddles are to be installed to support a long vertical run of conduit to ensure accuracy it would be appropriate to use a?
14.
If the voltage drop in an installation exceeds the permissible value it may be corrected by?
15.
Which of the following is a cartridge fuse?
16.
The installation which includes premade cables, distribution boxes and equipment all connected together with large plug and socket arrangement is a?
17.
What types of structures or installations need the highest possible degree of protection?
18.
Thermosplastic cable has insulation suitable for a conductor temperature of?
19.
In domestic lighting systems, the components used to control the circuits are?
20.
Which one of the following is the minimum conduit size suitable for a short straight run containing the following stranded cables: 4 x 1.5mm² and 3 x 2.5mm²?
21.
Which of the following is a miniture circuit breaker?
22.
Pre-existing damage should be identified then reported and confirmed with the?
23.
A room in which there is a 13A socket outlet is to be converted into a bathroom. The socket outlet must be?
24.
The correct title for the conductors that carry the electrical supply in between levels of a building is known as a?
25.
A circuit breaker offering circuit overload and short circuit protection, operates due to the following effects?
26.
The Health and Safety at Work Act...
27.
The term for a requirement in a Regulation as "absolute" means it?
28.
What cable is used to connect lots of computers in a LAN that is suitable for high rates of data transmission?
29.
When installing conduit along a wall, a distance saddle would be used why?
30.
The minimum bending radii of Mineral Insulated (MICC) cable is how many times the cable diameter for: rework (and non-rework)