Welcome to your 2365 625 Electrical design. This mock exam is not a substitute for proper teaching or revision and should only be used as a resource to prepare learners for the exam. The questions (along with the wording and diagrams) contained within the bank of this exam are purely made up by our lecturers and not copied from any actual qualification exam. So while this is an excellent free revision resource, please do not rely on these exam questions alone to help you be successful within your qualifications. When you are ready, please press "start quiz".
1.
The installation which includes premade cables, distribution boxes and equipment all connected together with large plug and socket arrangement is a?
2.
Which one of the following devices would be BEST suited to fixing 20mm² pvc conduit saddles to a concrete wall?
3.
Mineral insulated cables are sometimes provided with an overall covering of pvc to?
4.
The term for a requirement in a Regulation as "absolute" means it?
5.
The type of trunking that can be used as a circuit protective conductor is?
6.
What cable is used to connect lots of computers in a LAN that is suitable for high rates of data transmission?
7.
If conductors are not clean when making a joint with a crimping tool the most likely results will be?
8.
If class II and class I cabling is in the same cable space, how should it be placed?
9.
Which of the following is a miniture circuit breaker?
10.
A circuit installed to supply a fire panel would be identified as?
11.
The IET Wiring Regulations Appendices has information relating to cable selection on which of the following?
12.
Cables in wooden joists must be at least what distance from the top or bottom?
13.
When installing conduit along a wall, a distance saddle would be used why?
14.
Which of the following is a re-wireable fuse?
15.
The purpose of a protective device in a circuit is to?
16.
The overall diameter of large CSA multicore armoured cables may be reduced by?
17.
If conductors are not clean when making a joint with a crimping tool the most likely results will be?
18.
Which one of the following devices is suitable for an installation supplying an X-ray machine in a hospital?
19.
The most suitable type of wiring system for 3-phase electrical energy underground between buildings will be?
20.
Which one of the following is defined as a special location in BS 7671?
21.
Which one of the following is the minimum conduit size suitable for a short straight run containing the following stranded cables: 8 x 1.5mm² , 2 x 2.5mm² , 2 x 4.0mm²?
22.
Which one of the following is a short circuit protection device that is NOT activated by heat?
23.
Spring toggles are used to fix electrical equipment to?
24.
The disconnection time for ring or radial socket outlet circuits is?
26.
Which one of the following is the minimum conduit size suitable for a short straight run containing the following stranded cables: 4 x 1.5mm² and 3 x 2.5mm²?
27.
The minimum bending radii of Mineral Insulated (MICC) cable is how many times the cable diameter for: rework (and non-rework)
28.
What type of protection does a cable sheath provide?
29.
One of the main aims of the Health and Safety at Work Act 1974 is to secure the health safety and welfare of people where?
30.
Which of the following is NOT a statutory document?