Welcome to your H&S and Regulations Exam. When you are ready, please press "start quiz".
1.
Which specific location would not be included in the scope of BS7671?
2.
Multicore cables on a perforated tray are covered by reference method?
3.
A firefighters switch, shall be provided in the low voltage circuit supplying exterior electrical installations and interior discharge lighting operating at?
4.
What value of Earth Fault Loop Impedance would the Distributor Network Operator state for a dwelling with a TN-S earthing system?
5.
The ambient air temperature rating factor for 90ºC thermosetting cables operating in an ambient air temperature of 60ºC is?
6.
External influences coded AR are classified as?
7.
The ambient air temperature rating factor for 90ºC thermosetting cables operating in an ambient air temperature of 60ºC is?
8.
Which Classification does this symbol identify?
9.
Which of the following is not classed as notifiable work under Part P of the building regulations?
10.
The symbol used to show that a BS 88 device has a motor circuit application is?
11.
Which type of fire extinguisher is best used for an electrical hazard fire?
12.
Electric dodgems shall only be operated at voltages not exceeding?
13.
Which Classification does this symbol identify?
14.
An approximation of the prospective fault current between line conductors, of a 3 phase supply can be determined by?
15.
Electrical equipment installed outside in caravan parks shall be protected against mechanical stresses to a minimum of?
16.
Electrical equipment with double insulation provides?
18.
An accident occurs, the cause of which is found to be a piece of faulty equipment. The action to be taken would be?
19.
When making an assessment of the frequency and quality of maintenance, a factor to be considered is that:
20.
Which of the following statements is incorrect?
21.
The MAIN reason that good housekeeping is important in the workplace is to ?
22.
When protecting against burns, a metallic part intended to be touched but not hand held shall be limited to a maximum temperature of?
23.
Which part of the building regulations states information about drilling through externals walls, where moisture could cause an issue?
24.
Where a 3-core cable, with cores coloured brown, black and grey, is used as a switch wire for two-way or intermediate control. The terminations of the conductors shall be identified using?
25.
What does the abbreviation PEI stand for?
26.
Which of the following falls under the scope of BS7671
27.
The image represents which type of earthing system?
28.
What value of Earth Fault Loop Impedance would the Distributor Network Operator state for a dwelling with a TN-C-S earthing system?
29.
Which of the following is classed as non-notifiable work under Part P of the building regulations?
30.
On caravan sites, overhead conductors in areas subject to vehicle movement shall be placed at a minimum height above ground of?