Welcome to your Inspection and Testing. This mock exam is not a substitute for proper teaching or revision and should only be used as a resource to prepare learners for the exam. The questions (along with the wording and diagrams) contained within the bank of this exam are purely made up by our lecturers and not copied from any actual qualification exam. So while this is an excellent free revision resource, please do not rely on these exam questions alone to help you be successful within your qualifications. When you are ready, please press "start quiz".
1.
Which one of the following reasons would require an Electrical Installation Condition Report
2.
If an installation has no earth conductor what outcome would this be recorded as on an EICR?
3.
The main earthing conductor during an external loop impedance test should be
4.
Which document would be completed for an installation of an additional light fitting to an existing circuit?
5.
Resistance of a circuit would be most effectively measured using a?
6.
Which of the following conductors are classed as live conductors?
7.
A test of continuity at each socket-outlet of a ring final circuit is carried out to ensure that?
8.
The continuity of a main protective bonding conductor to a water pipe in a dwelling is to be tested. The cable CSA is 10mm and the length is 22m. The installation has been safely isolated for this test. Which additional piece of test equipment will be required for this test?
9.
If an exposed live part was was found on a socket outlet during an inspection on an initial verification what should the inspector do?
10.
A polarity test is conducted to verify that?
11.
The responsibility for giving the next inspection and testing date on an EIC lays upon on?
12.
The image represents which type of earthing system?
13.
As well as testing an RCD protected circuit for disconnection times we are required to operate the test button to
14.
The Continuity of a main protective bonding conductor to a water pipe in a dwelling is to be tested. The cable CSA is 10mm and the length is 22m. The installation has been safely isolated for this test. What is the only outcome that can be recorded on the Schedule of Inspections for this conductor?
15.
A R1+R2 reading at the extreme end of a 25m long 20A radial socket outlet circuit wired in 2.5mm Twin and Earth. What would be the approximate reading of R1 + R2?
16.
A finished consumer unit should be
17.
Failure to get a reading of polarity using test method one could indicate?
18.
If upon inspection there is a socket with 30mA RCD protection and 2.9m from Zone 1 in a bathroom, what outcome would this be recorded as on an EICR?
19.
The item shown in the photo should be used in what process?
20.
If upon inspection the top of a Distribution Board has an unused opening exceeding IP4X and with access to live parts, what outcome would this be recorded as on an EICR?
21.
If a copper conductor was doubled in length the resistance would
22.
Prior to performing an insulation resistance test, you should?
23.
What is the importance of verifying readings obtained with those listed within BS7671 and associated documents?
24.
If upon inspection the top of an Isolator has an unused opening exceeding IP4X and with access to live parts, what outcome would this be recorded as on an EICR?
25.
On an existing installation which of the following should be made available to the person conducting the inspection and test?
26.
Why is the Prospective Fault Current (Ipf) test carried out?
27.
The term Dutyholder used in the Electricity at work Regulations refers to the person
28.
What two documents must accompany an EICR for it to be valid?
29.
During one of the test methods for the continuity of CPC, GN3 recommends a temporary link should be made?
30.
Leaving incandescent lamps in circuit during an insulation resistance test may?